Emissions and Immunity

Radiated and conducted emissions testing at ETS are carried out at our low ambient 3/10 metre OATS and anechoic chamber.  Our fully automated testing ensures accurate measurements and fast turnaround.  All our facilities are environmentally controlled.

Our emissions test capability covers the frequency range 20 Hz to 40 GHz.  It enables us to undertake the following types of testing:

Conducted Emissions 20 Hz  – 400 MHz
Magnetic Field Emissions 20 Hz – 30 MHz
Electric Field Emissions 1 kHz – 40 GHz
Steady State Mains Supply Harmonics EN61000-3-2
Transitory Mains Supply Harmonics EN61000-3-2
Flicker EN61000-3-3
Inrush Current Measurements EN61000-3-3

Our immunity capabilities cover Commercial, Industrial and Military requirements and includes:

Electrostatic Discharge EN61000-4-2
Radiated Immunity EN61000-4-3
Fast Transients EN61000-4-4
Surges EN61000-4-5
Conducted immunity EN61000-4-6
Magnetic Immunity EN61000-4-8
Pulsed Magnetic Immunity EN61000-4-9
Voltage Dips/Interruptions EN61000-4-11
Voltage Fluctuations EN61000-4-14
DC Ripple Test EN61000-4-17
Frequency Variations Test EN61000-4-28
DC Dips Interruptions & Variations Test EN61000-4-29
Back
Our fully automated testing ensures accurate measurements and fast turnaround.