Radiated and conducted emissions testing at ETS are carried out at our low ambient 3/10 metre OATS and anechoic chamber. Our fully automated testing ensures accurate measurements and fast turnaround. All our facilities are environmentally controlled.
Our emissions test capability covers the frequency range 20 Hz to 40 GHz. It enables us to undertake the following types of testing:
Conducted Emissions | 20 Hz – 400 MHz |
Magnetic Field Emissions | 20 Hz – 30 MHz |
Electric Field Emissions | 1 kHz – 40 GHz |
Steady State Mains Supply Harmonics | EN61000-3-2 |
Transitory Mains Supply Harmonics | EN61000-3-2 |
Flicker | EN61000-3-3 |
Inrush Current Measurements | EN61000-3-3 |
Our immunity capabilities cover Commercial, Industrial and Military requirements and includes:
Electrostatic Discharge | EN61000-4-2 |
Radiated Immunity | EN61000-4-3 |
Fast Transients | EN61000-4-4 |
Surges | EN61000-4-5 |
Conducted immunity | EN61000-4-6 |
Magnetic Immunity | EN61000-4-8 |
Pulsed Magnetic Immunity | EN61000-4-9 |
Voltage Dips/Interruptions | EN61000-4-11 |
Voltage Fluctuations | EN61000-4-14 |
DC Ripple Test | EN61000-4-17 |
Frequency Variations Test | EN61000-4-28 |
DC Dips Interruptions & Variations Test | EN61000-4-29 |